Show simple record

dc.contributor.authorCrossley, James
dc.date.accessioned2011-12-07T02:01:07Z
dc.date.available2011-12-07T02:01:07Z
dc.date.issued2011en_NZ
dc.identifier.urihttps://hdl.handle.net/10652/1754
dc.description.abstractThe concept of sacroiliac joint (SIJ) motion dysfunction is an area of contention in manual therapy. Manual methods of assessing the SIJ have been constrained by poor reliability and a lack of an agreed ‘gold standard’. Doppler Imaging of Vibration has been proposed as one alternative method of evaluating SIJ motion. The aim of this thesis was to determine the intra-rater and inter-rater reliability of a group of observers scoring ‘Threshold Levels’ using pre-recorded video clips of Doppler Imaging of vibration (DIV) of the SIJ. 12 observers of varied clinical experience ranked 12 repeated and randomly assorted DIV clips. Intra-observer reliability ranged from ‘moderate’ to ‘very high’. Inter-observer reliability was ‘very high’ indicating that observers can reliably assess ‘Threshold Levels’ for DIV of the SIJ in pre-recorded video clips. The present study demonstrates that observers can make reliable judgments regarding Threshold Levels of DIV of the SIJ using video clips. Further research is required to establish the validity of the technique, including work demonstrating correlation with alternative measures of SIJ laxity/stiffness.en_NZ
dc.language.isoenen_NZ
dc.subjectsacroiliac jointen_NZ
dc.subjectmotionen_NZ
dc.subjectDoppleren_NZ
dc.subjectvibrationen_NZ
dc.subjectreliabilityen_NZ
dc.subjectsacroiliac joint dysfunctionen_NZ
dc.titleObserver reliability assessing ‘threshold levels’ in color Doppler imaging of vibration of the sacroiliac joint video clipsen_NZ
dc.typeMasters Thesisen_NZ
thesis.degree.nameMaster of Osteopathyen_NZ
thesis.degree.levelMastersen_NZ
thesis.degree.grantorUnitec Institute of Technologyen_NZ
dc.subject.marsden110499 Complementary and Alternative Medicine not elsewhere classifieden_NZ
dc.identifier.bibliographicCitationCrossley, J. (2011). Observer reliability assessing ‘threshold levels’ in color Doppler imaging of vibration of the sacroiliac joint video clips. (Unpublished document submitted in partial fulfilment of the requirements for the degree of Master of Osteopathy). Unitec Institute of Technology, Auckland, New Zealand. Retrieved from https://hdl.handle.net/10652/1754en
unitec.pages60en_NZ
unitec.publication.placeAuckland, New Zealanden_NZ


Files in this item

Thumbnail

This item appears in

Show simple record