    Modelling and monitoring the Unitec standard house to improve sustainability and indoor environmental quality.

    Tait, Robert

    Thumbnail
    Share
    View fulltext online
    Final report Tait 2010.pdf (176.1Kb)
    Date
    2011
    Citation:
    Tait, R. (2011). Modelling and monitoring the Unitec standard house to improve sustainability and indoor environmental quality. [unpublished Unitec Research Committee Research Report].
    Permanent link to Research Bank record:
    https://hdl.handle.net/10652/1659
    Abstract
    A testing facility has been established on the Unitec campus which allows monitoring of temperatures and humidity levels in a standard 3-bedroom house, operating as a control, to compare with the performance a second house modified with alternative materials or construction techniques. This appears to be very rare for thermal testing, with most experiments being carried out at an elemental level (ie individual materials within a laboratory setting), or in situ on a small section of construction as part of a larger building. A pilot study was completed to ensure that the monitoring process was functioning appropriately, and data collection commenced in December of the first test case, investigating the performance of a high-spec glazing unit to replace standard double-glazing. Initial findings indicate that the high-spec glazing makes a significant improvement in the thermal comfort of the house, which confirms results from laboratory-based materials tests. Monitoring is ongoing, and further analysis will provide more detailed evaluation of the benefits provided by the glazing in terms of year-round temperature performance and any resulting energy savings. In parallel with the physical testing of the house performance, computer simulations have been used to model the theoretical performance, and test the accuracy and ease of use of commonly used environmental modeling software. This part of the project has proven more difficult than expected, and has not yet produced results with the desired accuracy to compare against the monitored data. However, the difficulties experienced have provided an insight into potential problems and improvements that need to be addressed before these systems can be used more widely by practitioners.
    Keywords:
    Living environment, Alternative construction techniques, Alternative construction materials, Temperature, Humidity
    ANZSRC Field of Research:
    120202 Building Science and Techniques
    Copyright Holder:
    Robert Tait
    Rights:
    This digital work is protected by copyright. It may be consulted by you, provided you comply with the provisions of the Act and the following conditions of use: Any use you make of these documents or images must be for research or private study purposes only, and you may not make them available to any other person. You will recognise the author's and publishers rights and give due acknowledgement where appropriate.
    Metadata
    Show detailed record
    This item appears in
    • Unitec Research Committee Reports [58]

    Library home
    Send Feedback
    Research publications
    Unitec
    Moodle
    © Unitec Institute of Technology, Private Bag 92025, Victoria Street West, Auckland 1142
     

     

    Usage

     
     

    Usage Statistics

    For this itemFor the Research Bank

    Share

    About

    About Research BankResearch at UnitecContact us

    Help for authors  

    How to add researchOpen Access GuideVersions Toolkit

    Register for updates  

    LoginRegister

    Browse Research Bank  

    EverywhereAcademic study areasAuthorDateSubjectTitleType of researchSupervisorThis CollectionAuthorDateSubjectTitleType of researchSupervisor

    Library home
    Send Feedback
    Research publications
    Unitec
    Moodle
    © Unitec Institute of Technology, Private Bag 92025, Victoria Street West, Auckland 1142